| Specification |
Description |
|
Product description
|
|
Description
|
Industrial ETHERNET Rail Hub, Ethernet (10 Mbit/s)
|
|
Port type and quantity
|
1 x 10BASE2, CX cable, BNC socket,
1 x 10BASE-FL, MM cable, ST (BFOC) sockets,
2 x 10BASE-T, TP cable, RJ45 sockets
|
|
More Interfaces
|
|
Power supply/signaling contact
|
1 plug-in terminal block, 5-pin
|
|
Network size-length of cable
|
|
Twisted pair (TP)
|
0 - 100 m
|
|
Multimode fiber (MM) 50/125 µm
|
0 - 2300 m,
10 dB link budget at 850 nm,
A = 3 dB/km, 3 dB reserve, B = 400 MHz x km
|
|
Multimode fiber (MM) 62.5/125 µm
|
0 - 3100 m,
13 dB link budget at 850 nm,
A = 3.2 dB/km, 3 dB reserve, B = 200 MHz x km
|
|
Coaxial (CX)
|
0 -185 m
|
|
Network size - cascadibility
|
|
Propagation equivalent
|
port <-> port: 240 m
|
|
Path variability value
|
port <-> port: 3BT
|
|
Power requirements
|
|
Operating voltage
|
24 V DC (-25% to +30%)
|
|
Current consumption at 24 V DC
|
max. 300 mA
|
|
Service
|
|
Diagnostics
|
LEDs (power, data, link status, error),
signal contact/fault relais (24 V DC / 1 A)
|
|
Redundancy
|
|
Redundancy functions
|
redundant 24 V power supply
|
|
Ambient conditions
|
|
Operating temperature
|
0 °C to +60 °C
|
|
Storage/transport temperature
|
-25 °C to +70 °C
|
|
Relative humidity (non-condensing)
|
10% to 95%
|
|
MTBF
|
78.1 years; MIL-HDBK 217F: Gb 25 °C
|
|
Mechanical construction
|
|
Dimensions (W x H x D)
|
47 mm x 135 mm x 129 mm
|
|
Mounting
|
DIN Rail 35 mm
|
|
Weight
|
340 g
|
|
Protection class
|
IP 20
|
|
Mechanical stability
|
|
IEC 60068-2-27 shock
|
15 g, 11 ms duration, 18 shocks
|
|
IEC 60068-2-6 vibration
|
1 mm, 2 Hz - 13,2 Hz, 90 min.; 0,7g, 13,2 Hz - 100 Hz, 90 min.; 3,5 mm, 3 Hz - 9 Hz,
10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min
|
|
EMC interference immunity
|
|
EN 61000-4-2 electrostatic discharge (ESD)
|
6 kV contact discharge, 8 kV air discharche
|
|
EN 61000-4-3 electromagnetic field
|
10 V/m (80 - 2000 MHz)
|
|
EN 61000-4-4 fast transients (burst)
|
2 kV power line, 1 kV data line
|
|
EN 61000-4-5 surge voltage
|
power line: 2 kV (linie/earth), 1 kV (linie/line), 1 kV data line
|
|
EN 61000-4-6 conducted immunity
|
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)
|
|
EMC emitted immunity
|
|
FCC CFR47 Part 15
|
FCC CFR47 Part 15 Class A
|
|
EN 55022
|
EN 55022 Class A
|
|
Approvals
|
|
Germanischer Lloyd
|
Germanischer Lloyd (15662-00HH)
|
|
Scope of delivery and accessories
|
|
Scope of delivery
|
device, terminal block, operating instructions
|
|
Accessories to order separately
|
rail power supply RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame
|