| Specification |
Description |
|
Product description
|
|
Description
|
Entry Level Industrial ETHERNET Rail Switch,
store and forward switching mode,
Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
|
|
Port type and quantity
|
1 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
1 x 100BASE-FX, MM cable, SC sockets
|
|
More Interfaces
|
|
Power supply / signaling contact
|
1 plug-in terminal block, 3-pin / no signal contact
|
|
Network size - length of cable
|
|
Twisted pair (TP)
|
0 - 100 m
|
|
Multimode fiber (MM) 50/125 µm
|
0 - 5000 m,
8 dB link budget at 1300 nm,
A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
|
|
Multimode fiber (MM) 62.5/125 µm
|
0 - 4000 m,
11 dB Link budget at 1300 nm,
A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
|
|
Network sze - cascadibility
|
|
Line - / Star Topology
|
Any
|
|
Power requirements
|
|
Operating voltage
|
9,6 V DC - 32 V DC
|
|
Current consumption at 24 V DC
|
Max. 130 mA
|
|
Power consumption
|
Max. 3,0 W 10,2 Btu (IT)/h bei 24 V DC
|
|
Service
|
|
Diagnostics
|
LEDs (power, link status, data, data rate)
|
|
Ambient conditions
|
|
Operating temperature
|
-40 ºC to +70 ºC
|
|
Storage/transport temperature
|
-40 ºC to +70 ºC
|
|
Relative humidity (non-condensing)
|
10% to 95%
|
|
MTBF
|
128.1 years; MIL-HDBK 217F: Gb 25 °C
|
|
Mechanical constrution
|
|
Dimensions (W x H x D)
|
25 mm x 114 mm x 79 mm
|
|
Mounting
|
DIN Rail 35 mm
|
|
Weight
|
105 g
|
|
Protection class
|
IP 30
|
|
Mechanical stability
|
|
IEC 60068-2-27 shock
|
15 g, 11 ms duration, 18 shocks
|
|
IEC 60068-2-6 vibration
|
3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
|
|
EMC interference immunity
|
|
EN 61000-4-2 electrostatic discharge (ESD)
|
6 kV contact discharge, 8 kV air discharge
|
|
EN 61000-4-3 electromagnetic field
|
10 V/m (80 - 1000 MHz)
|
|
EN 61000-4-4 fast transients (burst)
|
2 kV power line, 4 kV data line
|
|
EN 61000-4-5 surge voltage
|
Power line: 2 kV (linie/earth), 1 kV (linie/line), 1 kV data line
|
|
EN 61000-4-6 conducted immunity
|
10 V (150 kHz - 80 kHz)
|
|
EMC emitted immunity
|
|
FCC CFR47 Part 15
|
FCC CFR47 Part 15 Class A
|
|
EN 55022
|
EN 55022 Class A
|
|
Approvals
|
|
Safety of industrial control equipment
|
cUL 508 (E175531)
|
|
Scope of delivery and accessories
|
|
Scope of delivery
|
Device, terminal block, operating manual
|
|
Accessories to order separately
|
Rail power supply RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame
|